|
| |
BACnet® Smart Actuator (B-SA)
BACnet® Smart Actuators (B-SA) are simple
control devices with limited resources; it is intended for specific applications.
Note: It is to
be expected that some products will not meet all of the profile requirements.
◄Return to the Product Catalog
American Auto-Matrix
|
Product |
Version |
Model |
Conforms to Profile |
PICS |
Listing Status |
|
NB-V3T |
1.10 |
NB-V3T |
√ |
PICS Document |
Not BTL Listed |
|
 |
|
|
The NB-V3T controllers are used in static pressure (NB-V3Tb) or airflow
(NB-V3Td). The NB-V3T controllers enable constant volume air handler
units (AHU) to supply variable amounts of air. The NB-V3Tb is
pre-configured as a bypass controller and provides five (5) digital
relay outputs, four (4) analog outputs, five (5) universal inputs, an
integrated pressure sensor and an actuator with feedback. The NB-V3Td
comes with a single universal input and an actuator with feedback and is
intended to control a single damper. |
|
|
|
|
|
|
|
|
Product |
Version |
Model |
Conforms to Profile |
PICS |
Listing Status |
|
NB-VAV |
1.10 |
NB-VAV |
√ |
PICS Document |
Not BTL Listed |
|
 |
|
|
The NB-VAV model controllers are variable air volume (VAV) and constant
air volume (CAV) terminal box digital controllers. There are five (5)
NB-VAV controller types, shown in the table below, that can be employed
in a number of different applications. |
|
|
|
|
|
|
|
Automated
Logic Corporation
|
Product |
Version |
Model |
Conforms to Profile |
PICS |
Listing Status |
|
VAV
Controller with Flow Sensor & Actuator |
1.2:14 |
U341v+ |
√ |
PICS Document |
BTL
Listed |
|
 |
|
Automated Logic's VAV
controller. This control module communicates as a slave device on an MS/TP
network at 9600 or 38400 baud and runs a built-in control algorithm that
receives parameters and status through BACnet objects. These BACnet
objects are usually monitored and controlled by a UNI module. All of
these models include a built-in flow sensor, and the “plus” models also
include an integral actuator.
|
|
|
|
|
|
|
|
|
VAV
Controller with Flow Sensor & Actuator |
1.2:14 |
U141v+ |
√ |
PICS Document |
BTL
Listed |
|
 |
|
Automated Logic's VAV
controller. This control module communicates as a slave device on an MS/TP
network at 9600 or 38400 baud and runs a built-in control algorithm that
receives parameters and status through BACnet objects. These BACnet
objects are usually monitored and controlled by a UNI module. All of
these models include a built-in flow sensor, and the “plus” models also
include an integral actuator.
|
|
|
|
|
|
|
|
|
VAV
Controller with Flow Sensor |
1.2:14 |
U341v |
√ |
PICS Document |
BTL
Listed |
|
 |
|
Automated Logic's VAV
controller. This control module communicates as a slave device on an MS/TP
network at 9600 or 38400 baud and runs a built-in control algorithm that
receives parameters and status through BACnet objects. These BACnet
objects are usually monitored and controlled by a UNI module. All of
these models include a built-in flow sensor, and the “plus” models also
include an integral actuator.
|
|
|
|
|
|
|
|
|
Unitary
Controller |
1.1:54 |
U551 |
√ |
PICS Document |
BTL
Listed |
|
 |
|
Automated Logic's zone
controller. This control module communicates as a slave device on an MS/TP
network at 9600 or 38400 baud and runs a built-in control algorithm that
receives parameters and status through BACnet objects. These BACnet
objects are usually monitored and controlled by a UNI module.
|
|
|
|
|
|
|
|
|
Unitary
Controller |
1.1:54 |
U253 |
√ |
PICS Document |
BTL
Listed |
|
 |
|
Automated Logic's zone
controller. This control module communicates as a slave device on an MS/TP
network at 9600 or 38400 baud and runs a built-in control algorithm that
receives parameters and status through BACnet objects. These BACnet
objects are usually monitored and controlled by a UNI module.
|
|
|
|
|
|
|
|
|
Unitary
Controller |
1.1:54 |
U220 |
√ |
PICS Document |
BTL
Listed |
|
 |
|
Automated Logic's zone
controller. This control module communicates as a slave device on an MS/TP
network at 9600 or 38400 baud and runs a built-in control algorithm that
receives parameters and status through BACnet objects. These BACnet
objects are usually monitored and controlled by a UNI module.
|
|
|
|
|
|
|
|
Teletrol Systems Inc.
|
Product |
Version |
Model |
Conforms to Profile |
PICS |
Listing Status |
|
XEM BACnet MS/TP DDC |
1.0 |
XEM-CPU-BMS-K-G1 |
√ |
PICS Document |
BTL Listed |
|
 |
|
This is a Building Controller for Building Automation System (BAS). In addition to control applications for Heating, Ventilation, Air Conditioning
the system. This system allows directly connection to other router device. This system is performed by powerful 32-bit microprocessor digital
technology. The control program is saved onto a flash memory. Running data is held in RAM, but it can be supported for approximately 72 hours
in case of power fail by means of battery backup. It has 16 analog/digital inputs, 8 analog/digital outputs also can provide a total of 128
physical points within max. 16 I/O modules.
|
|
|
|
|
|
|
|
Teletrol Systems Inc.
|
Product |
Version |
Model |
Conforms to Profile |
PICS |
Listing Status |
|
eTrac |
Rev. 1.00 |
01-182 |
√ |
PICS Document |
BTL
Listed |
|
 |
|
eTRAC is a
modular, low-cost, configurable I/O system for BACnet MS/TP. An eTRAC
Transceiver supports up to sixteen I/O points selected based on the
requirements of the control application. I/O types supported include
analog inputs and analog outputs, dry and wet binary inputs, and binary
outputs using triacs or relays for switching line voltage.
|
|
|
|
|
|
|
|
|